• Frigitron® 2000

    Description

    Frigitron® 2000 cools incoming air from low-pressure air sources such as ambient air pumps, including Bullard’s Free-Air pumps (EDP 30 and ADP20).

    More info
  • Frost Fighter IDF500

    Description

    The IDF500 comes standard with many features designed for safety, performance, and efficiency not found on competitive systems.  These include a fully-insulated jacket, industrial grade burner, stainless steel heat exchanger, satin-coated steel with powder-coated paint, independent fan and blower, heavy-duty 6-ply pneumatic tires, polarity and running lights, and a flexible duct attachment. Ductable up to 50ft.

    Heater Output: 420,000 BTU

    Technical information

    Download PDF
    More info
  • G2™ Deadman (Electric)

    Description

    • Electric controls are recommended for hose lengths 100 feet or longer
    • Longer lever provides optimal leverage, making the deadman easy to depress and hold comfortably in the "on" position
    • Handle and new button design allow operator to flex and relax hand position for better comfort while blasting, retaining safety while preventing unwanted shut-off
    • Curved body follows hose contour and provides a better fit to the blast hose
    • Easily adjusted for left or right-handed use
    • Military spec, high cycle rugged electric switch
    • Improved jacketing of the cord protects against fraying
    More info
  • G2™ Deadman (Pneumatic)

    Description

    • Longer lever provides optimal leverage, making the deadman easy to depress and hold comfortably in the "on" position
    • Handle and new button design allow operator to flex and relax hand position for better comfort while blasting, retaining safety while preventing unwanted shut-off
    • Curved body follows hose contour and provides a better fit to the blast hose
    • Easily adjusted for left or right-handed use
    • Wide port spacing for easy twinline connection
    • Visual markings and different size fittings help ensure a correct connection
    • Body and handle position are "reversed" to prevent dust and contaminants from getting under the handle when moving the blast hose assembly
    More info
  • G3™ Deadman (Electric)

    Description

    G3 2-Position Trigger Deadman. Requires 2 hose clamps.

    This handle can be used with any blast control setup, but comes standard with each new BAABS deadman system purchase.

    More info
  • G3™ Deadman (Pneumatic)

    Description

    G3 2-Position Trigger Deadman. Requires 2 hose clamps.

    This handle can be used with any blast control setup, but comes standard with each new BAABS deadman system purchase.

    More info
  • Garnet Return Program

    Description

    GMA is committed to offering a cost-effective alternative, providing additional value to their abrasive customers. Through advances in GMA's processing capabilities, they can now reprocess used garnet into a high-quality abrasive.

    By participating in the GMA Garnet Return Program, customers streamline their operations, dealing with fewer providers, stay compliant with regulations, sidestep hidden fees, and reduce their waste footprint.

    Collection Points: Fairless Hills, PA; Cincinnati, OH; Coos Bay, OR; Houston, TX; Seattle, WA

    *See PDF For More Information*

    Technical information

    Download PDF
    More info
  • Gaskets

    Description

    Standard Blast Couplings: 1-1/4" (Urethane)

    Standard and Nylon Blast Couplings: 1-1/4″ (Nitrile)

    Full Port Blast Coupling: 1-3/4″ (Nitrile)

    More info
  • Graco Airless Spray Guns

    Description

    Available Upon Request

    More info
  • Graco Tips & Guards

    Description

    Available Upon Request

    More info
  • GVX

    Description

    The Bullard GVX Respiratory System provides superior protection and comfort for abrasive blasting operations. With its lightweight design, this system offers a better fit and enhanced mobility, reducing fatigue during extended use. Designed for ease of use, the system also features simple maintenance and long-lasting performance, making it an ideal solution for improving safety and productivity on the job.

    Cape Options: 28", 38" 

    Climate Control: Cool Tube, Hot / Cool Tube, Frigitron Cool Tube

    Technical information

    Download PDF
    More info
  • GVX Hibernia Parka

    Description

    38" Parka suited for GVX Respirator System. Sold individually.

    Size: L, XL

     

    More info
  • GVX Inner Lens

    Description

    This lens sits just inside the seal of the helmet.

    Packaging: 25 Pack, Box of 8 Packs

     

    Technical information

    Download PDF
    More info
  • GVX Nylon Cape

    Description

    Suited for GVX Respirator System. Sold individually.

    Length: 28", 38"

     

    More info
  • GVX Outer Lens

    Description

    The outer lens snaps in behind the tear-off lenses (if applicable) in the helmet's face mask. If you don't use tear-off lenses, this will be the main lens in the front of the helmet. 

    Packaging: 25 Pack, Box of 8 Packs

     

    Technical information

    Download PDF
    More info
  • GVX Tear-Off Lens

    Description

    Snap the tear-off lenses in the helmet's mask first before the outer lens. Each lens has individually pre-folded tabs ensuring that workers tear off only one lens at a time.

    Packaging: 25 Pack, Box of 10 Packs

     

    Technical information

    Download PDF
    More info